Trilliant™ HC Healthcare Thermoplastics
Trilliant™ HC Healthcare Thermoplastics are specifically formulated to meet the high-performance material requirements of medical device manufacturers as well as demonstrate compliance with various regulatory bodies. These customizable formulations can replace traditional materials such as FR PC/ABS, FR PC/PET and FR COPE, offer improved chemical resistance to common disinfectants, achieve a UL 94 V-0 at 1.5 & V-1 at 0.75 flame rating when necessary, and can often be molded in existing PC/ABS tooling. With its improved long-term resistance to harsh disinfectants such as Virex® Tb, CaviCide™, Vesphene® IIse, and Super Sani-Cloth®,¹ Trilliant™ HC can help medical equipment manufacturers extend the overall service life of their devices.
Available in both natural and standard medical pre-colored products, the Trilliant HC family of materials are formulated without BPA ingredients.
¹Virex® is a trademark of Diversey, Inc.; CaviCide™ is a trademark of Metrex Research, LLC; Vesphene® is a trademark of Steris Corporation; and Sani-Cloth® is a trademark of Professional Disposables International, Inc.
Browse and download our literature to learn more about Avient solutions and services.
Important information about the health, safety and environmental impacts of Avient products.
Browse our library of product data sheets containing technical descriptions and details.
Technical information, design guides, processing information and more.
Product Series | Applications | Description / Product Features |
---|---|---|
Trilliant™ HC8910 and HC8920 | Medical Device Housings | Chemically resistant polymers formulated to withstand exposure to harsh chemicals and hospital-grade disinfectants |
Trilliant™ HC8910 GF Polyketone | Biopharmaceutical manufacturing clamps | Glass-filled polyketone (PK) formulations (10-30%) offer a nylon alternative with excellent chemical resistance, high temperature performance, and good wear resistance |
Trilliant™ HC 5210 Series | Pipette Tips | Electrically conductive thermoplastics specifically formulated with a unique combination of electrical conductivity, mechanical properties and processability |
Trilliant™ XR | MRI, X-ray and CT Scanner Components | Customizable, high-density polymer composite formulated to replace lead. Delivers radiation shielding performance comparable to lead |
NAME | CATEGORY | DESCRIPTION | |
---|---|---|---|
A Guide to Polyketone - Overview Brochure | Product/Service Overview | Take a comprehensive look at the performance and sustainability benefits of this next-gen material solution | View |
Auto-Injector Housing - Medical Delivery Device | Case Study (Snapshot) | A custom, impact-modified Trilliant™ HC formulation plus technical services met key needs and accelerated commercialization for a drug delivery device | View |
Chemical Resistance for Medical Devices - Technical Bulletin | Product/Service Overview | Explore various polymer performance to understand how material selection can prevent cracking and crazing, minimizing disinfectant-related failures in medical devices | View |
Chemically Resistant Polymers for Next Generation Devices | White Paper | Examine the damaging effects chemicals can have on the plastic components and learn about preventing environmental stress cracking in consumer and healthcare applications | View |
Chemically Resistant Polymers for Next Generation Healthcare and Consumer Products | Webinar | Learn more about considerations for chemically resistant materials for product development and durability in this free on-demand webinar | View |
Conductive Pipette Tips | Case Study (Snapshot) | Trilliant™ HC Conductive Formulation offered consistent electrical conductivity and provided high flow grade to conductive pipette tips | View |
Continuous Glucose Monitor | Case Study (Snapshot) | Healthcare device OEM benefitted from single source supplier for pre-colored solutions, Trilliant™ HC thermoplastics, and regulatory support | View |
Disinfectant Resistance for Medical Device Housings | Case Study | Manufacturer boosts disinfectant resistance for medical device housings using Trilliant HC High Performance Formulations | View |
Disinfectant Resistant Trilliant™ and Versaflex™ HC Materials | Product/Service Overview | Learn how chemically resistant Trilliant™ HC thermoplastics and Versaflex™ HC TPEs provide enhanced durability to withstand common hospital cleaners and disinfectants | View |
Environmental Stress Cracking Resistance (ESCR) Design Guide | Processing & Design Guides | Find out how part design can reduce stress in molded plastic parts and improve ESCR in your products | View |
Medical Device Disinfection: How to Prevent Cracking and Crazing | Technical Literature | Understand the material compatibility with common disinfectants of various materials used in healthcare applications | View |
Medical Device Housing | Case Study (Snapshot) | Trilliant™ HC8900 thermoplastics delivered superior chemical resistance after exposure to hospital-grade disinfectants | View |
Pipette Tips - Case Study | Case Study | Conductive pipette tip manufacturer uses Trilliant™ HC specialty formulations to increase savings, processing ease, toughness and performance | View |
Polyketone, a next generation sustainable nylon alternative | Webinar | Learn more about polyketone, how it compares to nylons, its sustainability value, and potential applications in this free on-demand webinar | View |
Specialty Engineered Materials for Healthcare | Product Selection Guide | View our portfolio on specialty engineered materials for healthcare | View |
Specialty Engineered Materials for Healthcare (Chinese) | Product Selection Guide | View our portfolio on specialty engineered materials for healthcare (Chinese language version) | View |
Surgical Stapler Housing | Case Study (Snapshot) | Delivered durable and aesthetically pleasing specialty polymer with the added benefit of processing flexibility without retooling | View |
TPEs and Specialty Engineered Materials for Auto-injector Pens | Video | Avient's TPEs and engineered materials for auto-injector pens offer excellent chemical and impact resistance, good self-lubrication functions, durability to extend product life, and compliance with biocompatibility and food-contact safety regulations. | View |
Trilliant™ Electrically Conductive Formulations for Pipette Tips - Application Bulletin | Application Overview | Explore how Trilliant™ conductive formulations help solve the performance challenges for pipette tip applications | View |
Trilliant™ Electrically Conductive Formulations for Pipette Tips - Application Bulletin (Chinese) | Application Overview | Explore how Trilliant™ conductive formulations help solve the performance challenges for pipette tip applications (Chinese language version) | View |
Trilliant™ HC Healthcare Thermoplastics - Glass-filled Polyketone Formulations | Product/Service Overview | Overview of performance and sustainability benefits of these glass-filled, polyketone (PK) materials for healthcare | View |
Trilliant™ HC Micro Wells | Case Study (Snapshot) | Trilliant HC thermoplastics provide chemical performance and regulatory compliance for microwell application | View |
Trilliant™ HC Thermoplastics and Versaflex™ HC TPEs for Surgical Stapler (Chinese) | Video | Explore more possibilities with Trilliant™ HC thermoplastics & Versaflex™ HC TPEs for surgical staplers | View |
Trilliant™ HC Thermoplastics and Versaflex™ HC TPEs for Surgical Stapler (English) | Video | Explore more possibilities with Trilliant™ HC thermoplastics & Versaflex™ HC TPEs for surgical staplers | View |
Trilliant™ HC8910 & HC8920 | Processing & Design Guides | Injection molding parameters including barrel temperatures, melt and mold temperatures, drying conditions, and processing guides for Trilliant™ HC8910 and HC8920 | View |
Tubing Clamp for Biopharmaceutical Supply Company | Case Study (Snapshot) | Glass-filled, polyketone-based Trilliant™ HC formulation delivers durability, nylon alternative with improved chemical resistance to meet supply and performance demands | View |